Local control unit of the SAOL system
Electronic multifunction alarm siren
Six-horn siren with six amplifiers and the longest standby time in the EWSA family — more than 30 days without mains power. Also plays messages, chimes and bugle calls.

| Frequency response | 200–7000 Hz |
|---|---|
| Alarm frequency | dual-tone 415/425 Hz |
| Sound level – directional horns (2 rows, 0°) | 112 dB(A) / 30 m |
| Sound level – back-to-back horns (1 row, 180°) | 115 dB(A) / 30 m |
| Number of horns | 6 |
| Number of amplifiers | 6 |
| Amplifier power | 900 W |
| Maintenance-free batteries | 2 × 12 V 38 Ah |
| Mains supply | AC 230 V 50 Hz |
| Standby power consumption | avg. 6 W |
| Power consumption while charging | max 100 W |
| Standby without mains power | > 30 days |
| Alarms within 48 h | > 20 alarms × 1 min (20 °C) |
| Communication | RS-485 (RJ45) |
| Horn array dimensions (W × H × D) | 840 × 2060 × 160 mm |
| Horn array material | aluminium alloy |
| Horn array weight | 58 kg |
| Horn array operating temperature | −50…+70 °C |
| Control cabinet dimensions | 600 × 600 × 210 mm |
| Cabinet weight incl. batteries | 75 kg |
| Cabinet operating temperature | −35…+70 °C |
| Environment | Range to threshold |
|---|---|
| Open terrain | ≈ 1.9 km |
| Small towns | ≈ 1.7 km |
| Housing estates | ≈ 1.2 km |
| Large cities | ≈ 880 m |
Estimate based on manufacturer curves: 115 dB(A) at 30 m (back-to-back horns), 6 dB loss per doubling of distance plus attenuation depending on the built environment. Actual range depends on terrain, mounting height and background noise — we run an acoustic simulation for each site.
Planning a warning system?
Let’s talkSiren and control selection, design and a quote — including for public tenders.